minicom disable hardware flow control command line. The monitor, mouse and keyboard are no longer required for system administration. minicom disable hardware flow control command line

 
 The monitor, mouse and keyboard are no longer required for system administrationminicom disable hardware flow control command line During my tests I use minicom, so the Hardware Flow Control is activated like you did with "stty -F /dev/ttymxc<n> crtscts" command

You can enter the ‘disable’ command to get out of secure mode, and ‘exit’ to exit the console completely. This will launch minicom, which you may then use: ctrl-A E. Change Configuration to 'MANUAL'. In the case of a DTE-to-DTE configuration, either device can act as a master. Following steps are executed in order: Open the minicom by using command sudo minicom -o -s -w. Onboard UART port with hardware flow control, for connecting with host boards like Arduino/STM32. serial. However it neither does not work on my machine. -R utf8 enables UTF-8 character set. Perform the “CCD open” process to enable functionality. GNSS disable, low active: GNSS control. When the related question is created, it will be automatically linked to the original question. After that, you may try the following. When you start minicom, the login prompt was already issued on terminal and is not displayed again. The command is as follows. A mode can be selected using the function uart_set_mode(). 1" open-source industrial HMI - an Integrated Device Master to unify data flow and manage the onsite device. A - Serial Device : /dev/ttyS0 B - Lockfile Location : /var/lock C - Callin Program : D - Callout Program : E - Bps/Par/Bits : 115200 8N1 F - Hardware Flow Control : No G - Software Flow Control : No. Many of the flag names in this C-structure are almost the same (and do the same thing) as the arguments to the stty command. py script? Please let me know if you have any questions and I look forward to your. Minicom is all command line, so if you are not. This is 2 when HW GPU scheduling is enabled and 1 after disabling via the settings UI. Minicom may be started with the -s switch and a configuration name. If the CNEW_RTSCTS or CRTSCTS constants are defined on your system then hardware flow control. On macOS, the name can be tricky for a user to determine since it can vary based several factors. No hardware flow control$ sudo minicom -c on. Minicom is a Linux program you can use to communicate with embedded target devices, either directly via through your computer’s COM port or with the Flyswatter. Restart the computer using the following command:. I have few odroid devices XU4 and HC1 and none of them receiving input while typing in putty or minicom. 6. My serial port setup is: Device: /dev/ttyUSB0. The Virtio-console is a simple device for data input and output. Hardware and Software Flow ControlIf the hardware flow control is disabled, the host may be woken from an UART byte reception (<wkup_byte>). You can have several minicom configuration files, for different serial hardware on your machine. 150. stty -ixon disables XON/XOFF output control; stty ixon enables it. See the man minicom for the truth. Minicom is commonly used for debugging and testing serial connections and for managing devices that use serial connections for communication. Next, locate an appropriate USB cable that has a USB Micro-B (5-pin) connector on one end and a regular USB Type A plug on the other end. To get 9600 bps 8N1 with no flow control: Code: Select all. UTF-8". 1. 1. +++ is usually in the string that is named "hangup string" so if you command minicom (or the like) to hangup it might. Type sudo usermod -a -G dialout USERNAME (replace USERNAME with your username) 2. Hardware flow control allows the communicating pieces of equipment to synchronize with each other. Modem A leased line is not connected to a telephone exchange and does not provide DC power, dial tone, busy tone or. To avoid this, use the '-w' command line option. When I type the AT commands, the letters I type do not appear, just the output message. You can use bg to have it resume in the background and fg to make it return to he foreground. Set the Speed to 115200 bits per second. OK. Code: # cat > newfile. Hit F to set the Hardware Flow Control to No. If I construct the script to exit and leave minicom running, minicom gets timestamps after the script completes. No verification of communication with serial. By default, Minicom will attempt to send the device various AT commands to configure it during the connection, which in this case won't do anything but clutter the screen with annoying text. I dont want to send a file or anything, just type back. Or replacing /dev/ttyUSB0 with whatever device file actually corresponds to your. "USB2. In my case, the master only has 4 UART pins: TX, RX, RTS, and CTS. [ Log in to get rid of this advertisement] Hi there, I'm trying to write a piece of software to test a UART driver and chip that I had been playing with. Enter "F" to change "Hardware Flow control" to NO. `hardflow BOOLEAN [ modem and direct only ]' The argument indicates whether the port supports hardware flow control. How to configure a serial port under Linux. Press F until “Hardware Flow Control is “No”. e: first use after installation), or if you find that your keyboard key presses are not sent to the RPi, you should make sure Hardware Flow Control is disabled. For a more complex network setup, refer to How to setup Networking for Embedded Linux Application Development. The no form of the command disables flow control on the individual ports. will use the ioctl syscall to enable / disable it) you don’t need to worry about setting the stty option. Set line discipline to i ( 0< i <127). Next, locate an appropriate USB cable that has a USB Mini-B (5-pin) connector on one end and a regular USB Type A plug on the other end. evenp or parity. * from a Terminal prompt to see a list. Ctrl-D on a blank line will do a. Get Minicom on your WSL1 distro. To disable flow control in GNU Screen, add the -ixon and/or -ixoff parameters after the serial speed as in the following example: $ Hardware Flow Control: No Software Flow Control: No Add linefeed: Yes Local echo: Yes Add carriage return: Yes Terminal Emulation: VT102. Now issue the AT commands to configure the modem. 4) Configure client serial port settings: In Serial port setup, set the following options A - Serial device: /dev/ttyS0 E - Bps/Par/Bits: 115200 8N1. The Virtio-console is a simple device for data input and output. Using the command stty -F /dev/ttyS1 -a I can confirm that crtscts has been enabled. Hit ENTER. Z. I am using Ubuntu 14. One stop bit. If the target does use flow control, it overrides the weakly asserted cts line and uses the rts info. Press F to disable the Hardware Flow Control. FAQs. ‣ For CentOS/RHEL: sudo yum install minicom -y ‣ For Ubuntu/Debian: sudo apt-get install minicom 3. A - Serial Device = /dev/ttyUSB0; F - Hardware Flow Control = No; press ESCTo add a serial port to an NST VM, using the following menu sequence on VMware Workstation: VM => Settings => Add => Serial Port => Next => Output to socket. The original code tends to cause the program to crash, but on occasion it does read from the board correctly, so the board is definitely transmitting something. The differences are apparently what you need to setup in your program. Then when a DTE (such as a PC) wants to stop the flow into it, it negates RTS. For software flow control, Windows and UNIX/Linux provide standard interfaces. The default. Sometimes it is the people no one can imagine anything of who do the things no one can imagine. I found the following tip (related to the same issue in utility screen) in this ESP8266 quick start guide (here the datasheet):. Exiting from bash should restart the player. Set the Connection type to Serial. 设置完成,回车,光标会回到“change which. The "Group" is the protocol used to send faxes between fax machines. Here I am explaining how to configure minicom in linux for a console connection to Cisco Nexus 5K switch. Neither port has a command applied directly related to 802. 1. 14. Navigate to the Line 1 level to display the config Line 1> prompt. • Hardware Flow Control: No • Software Flow Control: No. These. The following example show how to set the port 5/1 flow-control receive administration status to on (port requires far end to send flow-control packets):There are two ways of setting the audio output; using the desktop volume control, or using the raspi-config command line tool. You can include multiple commands. 1. -. A few of these tunables are available under Advanced Options (See System Tunables). Here is a basic configuration : Router# config terminal Router (config)# service linenumber Router (config)# line console 0 Router (config-line)# location Building-2A Router (config-line)# exec-timeout 30 0. When typing at the command line, the shell (such as the Bash shell) is reading what you type and reacting to it. This PDF document provides the detailed description of the AT commands for the SIM800 series modules, including SIM800, SIM800C, SIM800H and SIM800L. )Set the flow control to Software. By default minicom listens for serial data on /dev/modem, this is typically a symlink to the first serial TTY. Run wp disable on the Cr50 console. You can also use this to get more exhaustive list: vlc -H. PuTTY will then display the console. Open serial port setup and write serial device as /dev/ttyUSB0 and write Hardware Flow Control to NO. In PuTTY, the Flow Control option is in the settings tree under Connection, then Serial. Also opening minicom (minicom -D /dev/ttyS0 -b 115200) and the quitting directly using X. you need to check your baud rate too, ctrl-a p and then next lower or whatever. 1. type "F" until hardware flow control is "No" type "G" until software flow control is "No" <enter> to leave menu ; modem and dialing; menu. As far as I know, RTS/CTS protect the slave's receive buffer from overflowing. stty -ixon disables XON/XOFF output control; stty ixon enables it. 1 stop bit. Enter Serial port setup. reTerminal DM is A 10. 0. Modem Requirements. I've setup the terminal application for line wrapping but I'd like it to go to the beginning of the next line when receiving a line feed character from my serial device. • You have connected. I managed to get this working once, but when I tried a while later the changes didn't work. host $ sudo apt-get install minicom Once minicom is installed it will not be setup to talk properly to a board through the UART port, to change the configuration open up a terminal window and run sudo minicom -s at which point you will have to provide. However, connecting mincom to the port /dev/ttyS0 and trying to disable flow control (as it should not be in use) still freezes the system. is a full-screen serial terminal emulation package, very much like the classic. Go to "Serial port setup". minicom ] [. are selected. Every character you type in minicom will then be looped back. Input queue: 0/75/0/0 ( size /max/ drops / flushes ); Total output drops: 90. --flow | -f Defines the flow-control mode to set the serial-port to. By default, minicom will not wrap longs lines of text, which causes them to run off the edge of your terminal screen. minicom version is 2. )1. ini with a text editor and remove the two lines with "m_iRenderResolutionX" and ""m_iRenderResolutionY". (This is MAC dependent, and requires a. Minicom decides offline/online based on whether DCD line is connected or not. This is a very old program and some of the options don;t make sense anymore. You have to modify minicom source code to support non-standard baudrates. On minicom you appear to first sent ate, don't see you sending that in your terribly formatted Python code. Must be one of: - Start the configuration mode of minicom. Enter IP address, Netmask and Gateway. Figure 7: Hardware Flow Control (F) DisabledConnect a USB Cable ¶. what are you sending to the computer? can you use a paperclip between socket 2 and 3 on the serial port to make a loop back. This could be a hardware problem such as bad contact, or a firmware issue with the device. Open a terminal and open minicom setup. 2. You can use Shift + E to setup the baudrate, choose 115200 and hit Enter to confirm. in Windows Command-Prompt window, find-out serial port list with below command: list ports & device names: chgport. Use the "Type" pull-down menu and select "Application in terminal". The flow control may also be present in the shorthand notation: 8-N-1-None, which stands for no flow control. All devices on Unix are mapped to a device file, the serial ports would be /dev/ttyS0 /dev/ttyS1. Some switch chips are capable of reporting statistics, this can be useful to monitor. 此时光标在“change which setting”后面停留,它的上面有如下菜单:. 我们只需输入上面对应的字母,就可以进如相应的菜单进行设置。. Orig: "Hardware: Yes, Software: No" Works: "Hardware: No, Software: No" Works: "Hardware: No, Software: Yes" Weird that Hyperterminal works with Flow Control is set to "Hardware" but minicom doesn't let me type anything. For Android and Windows (Cygwin) installations, the Minicom configuration files are at: For Ubuntu Linux installations, the Minicom configuration files are stored in: Unfortunately it seems that i can only connect to the modem, when hardware & software flow control are disabled. history—Control the CLI command history cache. #apt-get install minicom. you need to check your baud rate too, ctrl-a p and then next. stty -F /dev/ttyS2 crtscts or stty crtscts < /dev/ttyS2. If I do this from a terminal on my host machine (like gnome-terminal) I can hit "Ctrl+c" and it will exit and give me another prompt. . Click Close. Off or XON/OFF. If you don't see the Driver tab or that. Set the Connection type to Serial. there is no information about "serial port" in X11 system "HardWare exploer". If you are processing the information and can't receive any more because your input buffers are full, then you would send XOFF to tell the other party to stop sending. The program can be run from the command line and provides a user-friendly interface for configuring the serial port and setting options such as baud rate, flow control, and parity. -D /dev/ttyUSB0: chọn cổng USB0 giao tiếp với board. You can use the W configuration setting to change. a communication program include script language , capture to file, multiple users with individual configurations, A with all the documention found here, this is tersified and arranged in what I feel is a sensible order. Type: ATI. Syntax: [no] interface <port-list> flow-control Enables or disables flow control packets on the port. The control unit can disable SDMMC_CK generation when the bus is idle. Press F if Hardware Flow Control says Yes. The data that is coming from the NFC shield is coming at 115200 baud, so we need to configure minicom. 4 RTS/CTS and DTR/DSR Flow Control . You can use Shift + A to setup the serial device, hit Enter to confirm. Root edits the system-wide defaults in /etc/minirc. Save the setup as the default setup. They are called RTS (Request to Send) and CTS (Clear to Send). Hardware flow control at the serial port works like this: The two pins, RTS (Request to send) and CTS (Clear to send) are used. minicom -s. It is a useful reference for developers who want to use the SIM800 series modules in their projects. How to configure a serial port under Linux. Default value is 'yes' because older NICs do not support it. It is only modified by the user in the callback, and read by the main while loop. In general, stty -flag disables the corresponding termios flag, stty flag enables it. 1 OPTIONS: I18n Compiled on Apr 28 2012, 19:24:31. Set Software flow control to No using the G key. Press ESC. To get 9600 bps 8N1 with no flow control: Code: Select all. The -w option enables line-wrapping. will create a . ls -l /dev/ttyS1. One big advantage of minicom is that it allows one to easily capture text into a file. To exit Minicom when in terminal mode press 'Ctrl-A' to get a message bar at the bottom of the terminal window and then press 'X'. This is "hardware" flow control. Having to run minicom prior to your program implies that your program in not initializing the serial port. (minicom -s ; go to Serial Port Setup; last two lines are Hardware and Software Flow control; just set NO both) Turn on echo ( ctrl + A after turn on minicom, then press E) to check whether you send something is good idea too. val – Value to set to the line control. After modify it press enter twice. inter_byte_timeout – Inter-character timeout, None to disable (default). The default communication parameters should. Based on Raspberry Pi CM4, and as a Panel PC, HMI, PLC, IIoT Gateway all-in-one device, reTerminal DM is a new generation of interactive sensing hub with an IP65. . A Universal Asynchronous Receiver-Transmitter (UART) is a hardware serial communication bus used by most processors and chips. The no form of the command disables flow control on the individual ports. This module can be executed to get a list of ports ( python -m serial. The data rate that this occurs at will depend on. This can be done with a text editor such as nano or Vim by entering the following command: sudo nano /boot/config. ctrl – The line control to manipulate (see enum uart_line_ctrl). Note: If you are using a USB to serial adapter use ttyUSB0 instead of tty0. Steps. There is no standard "command" one side can send to enable or disable flow control on the remote side. The commands that I have used to communicate with minicom are. e Rx,Tx and GND, which does. It allows the receiving piece of equipment to indicate that it is ready to receive the data that is being sent. Sometimes Minicom will use. 串口调试利器--minicom [toc] 因为现在电脑基本不配备串行接口,所以,usb转串口成为硬件调试时的必然选择。目前知道的,PL2303的驱动是有的,在dev下的名称是ttyUSB*。 Minicom,是Linux下应用比较广泛的串口软件,这里简单介绍minicom使用。The system now needs to run a hardware test to start the encryption process. This allows a. Basically microsofts hardware flow control is not hardware but software flow control, even if the hardware does have hardware flow control capabilities microsft's drivers were not. You can use Shift + A to setup the serial device, hit Enter to confirm. $sudo minicom -b 9600 -D /dev/ttyS1 Now press CTRL+A and then Z, and then O, and select serial port setup. Synopsis. 1 Answer Sorted by: 6 Try Minicom first and see what your serial port returns. The settings in the Terminal Emulator software need to be set correctly; otherwise, unintelligible characters show up on the screen. Open the minicom application. When in doubt, run ls-l /dev/cu. To configure a modem use the command minicom -o console to start Minicom without sending an initialization string to the modem. Bps: 115200 8N1. serial. What does clear output buffer do in pyserial? Clear output buffer, aborting the current output and discarding all that is in the buffer. Download and install Termite. after turning off hardware flow control in minicom you have to exit and then return for it to take effect. Minicom Installation. First task is to unbind console from serial simply by disabling entry in /system console menu: [admin@MikroTik] /system console> print Flags: X - disabled, U - used, F - free # PORT TERM 0 X serial0 vt102. Screen is somewhat persnickety for Serial Port work so try Minicom. g. This enables one to print messages to the console, and it very similar to printf (). The problem is I cannot write anything back from keyboard. In minicom disable the hardware handshake, otherwise ctrl-C or ctrl-D will not work: within minicom press ctrl-A z (minicom command summary) O (configuration) Serial port setup; D (Hardware Flow Control: no) G (Software Flow Control: no) Save setup as dft in configuration Set Hardware flow control to No using the F key. I tried using minicom in Raspberry-pi buster. However i may see full boot log in terminal. To delete a power plan on Windows 10 with the powercfg command tool, use these steps: Open Start. Log into your hardware device as root. Enter a and the cursor should move to the end of A - Serial Device : /dev/modem . If you do not see output from the board, press Enter several times until you see the prompt. It switches control key from Ctrl+a to Alt (in my case) for minicom and now Ctrl+a d work properly for screen detach. Use up and down arrows to select menus. Check speed too. bashrc file, setting. Connects to a named pipe. Note I've change the default port from /dev/modem to /dev/ttyS4 and the speed, in my case, to. Run the minicom command with the option -con. Naturally this requires the other side to support it, so if only hardware flow control is supported then it won't be a viable solution. Disable hardware flow control on the access server with the no flowcontrol hardware line configuration command, and then enable hardware flow control on the modem via a reverse Telnet session. Connect a USB Cable ¶. Configuring minicom (Linux) Minicom should be started with the -D <serial device> command line switch e. Reset the board, and wait for a moment. The most common setting here is to disable it. macOS¶. If this value is set to 'no', the router automatically detects whether the NIC is connected with a device in the network or not. Add dtoverlay=uart-ctsrts to /boot/config. Adding the -U parameter to the screen command line arguments forces it to use UTF-8 for. Performs device factory reset that is hardware reset preceded by erasing of the whole Matter settings stored in a non-volatile memory. How to configure a serial port under Linux. These. -errno – Other negative errno value in. Hitting any key will restart the flow after a flow. Despite a user interface less modern than that of seyon, minicom is the more popular Linux communications program. Set Hardware flow control to No using the F key. Figure 2. I) A - * - * - * - I - Screen and keyboard: P - Add linefeed Save setup as dfl then Exit. g. - s - start the script: script. If I start minicom with the script, I get no timestamps in the log. In PuTTY, the Flow Control option is. Here is an example of how to configure these settings on a. 适于在linux通过超级终端对嵌入式设备行管理. config file empty and use command. py v 2. But some program (s) may still be writing stuff 'live', until explicitly ejected/removed. 10. 2. If this bit is set, enable flow control of input based on the RTS wire (RS232 protocol). Hardware flow control must be disabled for you to be able to send inputs to terminal in typical PL2303 USB to Serial cables. PuTTY in Windows ¶. The hardware flow control logic stops the SDMMC_CK pin signals and freezes the DPSM when a risk of underrun/ overrun is detected. 2. Answer an Incoming call – ATA. 1. This will set the baud rate to 9600, 8 bits, 1 stop bit, no parity: stty -F /dev/ttyS0 9600 cs8 -cstopb -parenb. PuTTY will then display the console. The c specifies the color display and on tells minicom to display the interface in color. . Minicom is a serial communication program, which we can use with the Dragon12 board. The serial sensor platform is using the data provided by a device connected to the serial port of the system where Home Assistant is running. This article explains how to setup a ELM32x OBD-II. When one DTE device wishes to transmit data, the DTE device pulls the RTS line low, which signals the slave device, through its CTS input, to begin to monitor its. Choose “Exit from Minicom” and the menus will close. ESP32-WROOM-32 Series. By using the RX/TX/GND pins on the GPIO header you can get a standard serial port with software flow control (meaning you can use ^S and ^Q to stop and start the flow of characters). Returns: COMMAND-LINE -s, --setupS etup. Use the admin password for verification. For software flow control there are 3 settings: ixon, ixoff, and ixany. It works for me. 14. Warning. At the command line, enter: minicom -s; Enter the Serial port setup menu and specify the following settings: A - Serial Device : /dev/ttyUSB0 B - Lockfile Location : /var/lock C - Callin Program : D - Callout Program : E - Bps/Par/Bits : 9600 8N1 F - Hardware Flow Control : No G - Software Flow Control : No reTerminal DM Getting Started. e. Power cycle (switch off and then on) the router and press the SPACEBAR for 10-15 seconds in order to generate a signal similar to the break sequence. We recommend that you use hardware flow control. The easiest way to do that would be run:If you choose a 5 wire setup with RTS and CTS lines, then select hardware control, and no software control. Adding the -U parameter to the screen command line arguments forces it to use UTF-8 for. If you are sure about the settings (Baud, parity, flow control) you use, I think that minicom does not "hang" but rather just "does not show anything". Tried to change baud, parity, flow control settings with no effect. From the command line, you'd use the (horribly confusing) stty command: Code: Select all. minicom 的配置. NOTE: IF the console interface does not start, you may exit the Minicom interface by pressing CTRL+A, then press Q to quit. Example: If a type "AT" and press enter, the "AT" doest not appear, but the "OK" output message appear normally. Get root access by typing the command root. You should just press enter. Hardware vs. 3-rc4 but still found the same logs, now I installed 1. list all CON (console), available COM & LPT devices: mode. For an example of changing these settings, press F to disable Hardware Flow Control. F - Hardware Flow Control : Yes G - Software Flow Control : No Change which setting? 9. The terminal help screen: ** p - set speed m - no CR/NL mapping n - no flow control h - hardware flow control 1. 2) Probably something is. uses 115200 for the bit rate, and assuming you want the VGA to still be a console), you might want the parameters: console=ttyS0,115200n8r console=tty0. Just hit Ctrl Z. Search for Command Prompt, right-click the top result, and select the Run as administrator option. 288998] usb 2-2: new full-speed USB device number 11 using. I am using minicom to capture bluetooth data. If it does not, hardware flow control will not be turned on for this port. It covers the syntax, parameters, responses and examples of each command. Open a command line terminal window and enter the following to start the Minicom setup. See 'man minicom' for more information. If the host name does not include a , the . py script? Please let me know if you have any questions and I look. Also press F to disable Hardware Flow Control. picocom accepts the following command-line options --baud | -b Defines the baud-rate to set the serial-port (terminal) to. Note 2: Connection between CTS/RTS is optional, depending on whether you want to use hardware flow control. Upvoting this answer as the best way to disable software flow control. But not with mgetty. Port blocking (unknown multicast and unknown unicast traffic) Disabled (not blocked) (Layer 2 interfaces only). Flow control options. The Minicom command line in Running Minicom includes the -w option, which enables line wrapping. Before launching minicom, you must configure it. Nếu bạn Enter mà không thấy log thì có thể hardware flow control. minicom can be made to always run in color by adding the 2 lines shown below to. These wires are cross-coupled between the two devices, so RTS on one device isPuTTY in Windows ¶. - Serial port configuration: minicom - Used Configuration: 9600 8N2 ,Hardware Control Flow: No, Software Control Flow: No - Status: Online. Apply power to the board. If the display isn't colored, arrow down to Exit from Minicom. minicom is a communication program which somewhat resembles the shareware program TELIX but is free with source code and runs under most Unices. Press the down cursor key twice to move to “Serial port setup”. O. Hardware flow is typically controlled by the DTE device, which could be considered a ‘master’ device. pu linewrap Yes. e. These codes are generally called XOFF and XON (from "transmit off" and "transmit on", respectively). When you set up the connection, use these settings: Bits per sec : 9600 Data bits : 8 Parity : none Stop bits : 1 Flow control : none. This should bring up a colorful display listing the different settings. Secure web mode is a secure connection. -ENOSYS – If this function is not implemented. Wait for some time in press CTRL-A z for help on special keys screen. The name of my serial port is /dev/ttyUSB0 according to following command: dmesg | grep tty [ 0. Connecting works fine with minicom, when flow control is disabled, I can send AT commands and so on. A - serial device : /dev/ttyUSB1 E - Bps/par/bits: 115200 8N1 F - Hardware flow control :NO G - Software Flow contrl : No. To check what kind of data is arriving at your serial port, use a command-line tool like minicom or picocom on Linux, on a. Reset the board, and wait for a moment. RING ATA OK. Our objective in this project is to send data via UART from an STM32 chip to a host computer (which could be a Windows, Linux or Mac machine) and display the message on the host’s screen. This is called a ‘command line’. Negated "Request To Send" (-12 volts) means "request NOT to send to me" (stop sending). py works well with the Arduino. stty -F /dev/ttyUSBx -crtscts. After reTerminal has made changes, you will see the following text appear on the screen. In my attempts to google for a solution, I saw suggestions for a "flowcontrol" and "negotiation forced" IOS interface commands.